Solenoid valve troubleshooting

2023-05-26

The solenoid valve does not work when energized

Check whether the power cable is bad → Reconnect the power cable to the connector

Check whether the power supply voltage is within the ± working range -→ normal position range

Whether the coil is unwelded → rewelded

Coil short circuit → Replace coil

Whether the working pressure difference is inappropriate → adjust the pressure difference → or replace the appropriate solenoid valve

The fluid temperature is too high → replace the appropriate solenoid valve

Impurities make the main valve core and moving core of the solenoid valve stuck to clean, if there is seal damage should be replaced and the filter should be installed

The liquid viscosity is too large, the frequency is too high and the life has to → replace the product

The solenoid valve cannot be closed

The seal of the main spool or iron moving core has been damaged → Replace the seal

Fluid temperature, viscosity is too high to replace the solenoid valve

There are impurities into the solenoid valve spool or moving core → clean

Spring life has reached or deformation → replacement

Throttle hole balance hole blockage → timely cleaning

The working frequency is too high or the service life has reached → change the product or update the product

Other circumstances

Internal leakage → Check whether the seal is damaged and the spring is improperly assembled

External leakage → loose connection or broken seal → tighten screws or replace seals

Noise when energized → fasteners on the head loosen and tighten. Voltage fluctuation is not allowed within the range, adjust the voltage. Core suction surface impurities or uneven, timely cleaning or replacement.